Servo Controlled Voltage Stabilizers – 3 Phase Oil Cooled
Provides perfectly stable output even under severe conditions of unbalanced voltage conditions. Ideal to protect the electrical and electronic equipments from high and low voltage.
Protections
- Single Phasing Prevention
- Output Electronic Over Load Protection
- Phase Reversal Protection
- Input Short Circuit Protection with MCB
- Input Over Load Protection with MCB
- Output Low Voltage Protection
- Output High Voltage Protection
- Audio Alarm for Protections
Indications
- Mains Input on 3 LED Indications,
- 3ph output on indication
- Phase Reversal indication
- over Load indication
Indications in LCD Display
- Input High and Input low
- Output on indication
- Output high Cutoff and Output Low Cutoff
Programmable Parameters
- Output voltage set ( 210-245V)
- Output Low Voltage Cutoff
- Output High Voltage Cutoff
- Input Low on LCD Display
- Input High on LCD Display
- Sensitivity / Regulation
- Over Load Cutoff
- CT full scale
Programmable Control Timings
- Over load Cutoff Time
- Auto Restart Time
- On & Off Delay Time
Programmable Controls
- Display Scrolling – Auto / Manual
- Start / Stop Buttons
- Menu / Start / Stop / Reset / Log Button
- Data Log: Last 100 fault events log with Date & Time stamp and works on FIFO basis.
- Very Important For CSD
- Analysis Problems
Input voltage range | 300 – 460v 340 – 480v 360 – 460v ac 3 ph |
Output voltage(3 ph) | 415v |
Ac system | Unbalanced 4 wire – R Y B N |
Connections | star |
Operating frequency | 47 to 53 hz |
Output voltage adjustable | 380 to 415v ac in 3 ph |
Output voltage regulation | + 1% (no load) |
Output voltage regulation | + 1% (full load) |
Overload capacity | 120% Correction Rate – 60 25 15V per Sec-3 Phase |
Waveform Distortion | nil |
Output Waveform/td> | true |
Reproduction of Input Insulation | Class B |
Short Circuit period & Percentage | 300% for 250 Milli Sec. 0 0 |
Normal Operation Temperature | 0 C to 45 C 0 |
Climate Conditions | 90% Rh Max |
Non Condensing at 35 C Type of Cooling | Natural Oil cooled up to 5000 KVA |
Mode of system | Fully Automatic System |
Construction | As per IS – 9815 1994 |
- Quick response time 10milli sec (half a cycle)
- Very high efficiency above 98%
- Excellent regulation as high as +- 0.5%
- Micro controller
- Controlled system
- Wide input range of operations & high speed of correction Protections
- Single Phasing Prevention
- Output Electronic Over Load Protection
- Phase Reversal Protection
- Input Short Circuit Protection with MCB
- Input Over Load Protection with MCB
- Output Low Voltage Protection
- Output High Voltage Protection
- Audio Alarm for Protections