3 Phase Air Cooled Servo Controlled Voltage Stabilizers
Provides perfectly stable output even under severe conditions of unbalanced voltage conditions. Ideal to protect the electrical and electronic equipments from high and low voltage.
Protections
- Single Phasing Prevention
- Output Electronic Over Load Protection
- Phase Reversal Protection
- Input Short Circuit Protection with MCB
- Input Over Load Protection with MCB
- Output Low Voltage Protection
- Output High Voltage Protection
- Audio Alarm for Protections
Indications
- Mains Input on 3 LED Indications,
- 3ph output on indication
- Phase Reversal indication
- over Load indication
Indications in LCD Display
- Input High and Input low
- Output on indication
- Output high Cutoff and Output Low Cutoff
Programmable Parameters
- Output voltage set ( 210-245V)
- Output Low Voltage Cutoff
- Output High Voltage Cutoff
- Input Low on LCD Display
- Input High on LCD Display
- Sensitivity / Regulation
- Over Load Cutoff
- CT full scale
Programmable Control Timings
- Over load Cutoff Time
- Auto Restart Time
- On & Off Delay Time
Programmable Controls
- Display Scrolling – Auto / Manual
- Start / Stop Buttons
- Menu / Start / Stop / Reset / Log Button
- Data Log: Last 100 fault events log with Date & Time stamp and works on FIFO basis.
- Very Important For CSD
- Analysis Problems
Input voltage range | 300 – 460v 340 – 480v 360 – 460v ac 3 ph |
Output voltage(3 ph) | 415v |
Ac system | unbalanced |
wire | r y b n |
Connections | star |
Operating frequency | 47 to 53 hz |
Output voltage adjustable | 380 to 415v ac in 3 ph |
Output voltage regulation | + 1% (no load) |
Output voltage regulation | + 1% (full load) |
Overload capacity | 120% |
Correction rate | 60 30 25v per sec-3 phase |
Waveform distortion | nil |
Output waveform | true |
Reproduction of input insulation | class f short circuit |
Period & percentage | 300% for 250 milli sec. 0 0 normal |
Operation temperature | 0 c to 45 c 0 |
Climate conditions | 90% rh max. |
Non condensing | 35 c |
Type of cooling | natural air cooled up to 600 kva |
Mode of system | fully automatic system |
Construction | as per is – 9815 1994 |
- 1.Quick response time 10 milli sec (half a cycle) very high efficiency above 98% excellent regulation as high as +- 0.5% micro controller
- 2.Controlled system wide input range of operations & high speed of correction metering on lcd display
- 3.3ph input voltage ph to ph and ph to neutral
- 4.3ph output voltage ph to ph and ph to neutral system frequency
- 5.Output current on each ph protections
- 6.Single phasing prevention
- 7.Output electronic over load protection
- 8.Phase reversal protection
- 9.Input short circuit protection with mcb
- 10.Input over load protection with mcb
- 11.Output low voltage protection
- 12.Output high voltage protection
- 13.Audio alarm for protections indications mains input on 3 led indications 3ph output on indication phase reversal indication over load indication